Comprehensive & Fine Display
20 characters 4 liner LCD Provides Continuous display of battery life information, infusion set details, keypad locking status, and alarm messages on alarm generation and relevant help on pressing HELP key.
7-segment LED display
All operation status I-mac 304-D are clearly shown on 7- segments LED displays.
Three different modes for infusion
- Rate Mode
- Volume Target Mode
- Time Target Mode
Customizable setup as per user’s choice
-
12 factory preset and 2 customized IV sets library along with facility to set default infusion set.
-
5 levels for Alarm sound tone
-
5 levels for KVO flow rate
-
5 levels for keypad tone
-
Facility to set default BOLUS RATE
-
Facility to set default BOLUS VOLUME
-
Facility to set default air bubble size
-
Facility to set default accumulated bubble volume over the period of time
-
Facility to set default level of occlusion
-
Facility to set default Infusion mode for simplicity
Simplified selection & data entry
9 Self-explanatory keys & rotating encoder makes the parameter easy to set the parameters and select various options.
Self Explanatory Control Panel
The control panel is self-explanatory with abbreviated operating instructions on LCD. Easy-to-read liquid-crystal displays all essential data in large size numbers, reducing the chance of erroneous readings. LCD provided with backlight for viewing in dark environments.
Easy identification of alarm condition
Obvious and recognizable attention lights Flashing Back- light of LCD Display for Audible and Visible alarm Function
Free Flow Protection
Tubing clamp (Stopper) mechanism automatically closes the IV tubing to prevent unrestricted flow of solution to the patient when the door is opened.
Communication Port
RS - 232C connector for external communication and to upgrade.
Air bubble detector
Air bubble detector can detect bubble size between 50 to 150 micro liters (User settable). Alarm available for air bubble volume accumulated over time (1ml over 0.5h)
Settable Downstream Occlusion
New improved Pressure sensor provides the facility of settable downstream occlusion in three steps.
Upstream Occlusion detection
This optional feature provides the facility to detect upstream occlusion.
Easy Battery Replacement
The battery pack can easily be replaced simply by opening the battery cover at the back of the unit.
Self-testing Function
After power turned on, the microprocessor in the I-mac 504V automatically executes a self-diagnostic testing in order to ensure that all functions are working properly. That also monitors every corner during infusion.
Key Pad Locking
A built in safely feature prevents any change the parameter if any key is accidentally pressed during infusion. Option is provided to DISABLE the Feature in the set up menu, if not needed.
Lighted Status Indicator
Run and Mains Indicators allows the operating status to be checked from long distance also.
The Handy drop Pump
Small size, low weight and high-technology, incorporated into a compact design. Quick and simple mounting at the bedside, via universal clamp