Welcome to Our Plenum Technologies

Plenum's Volumetric Infusion Pump - Imac 304D  

Specifications :

Download Specifications of IMAC 504V in WORD format


Download Specifications of IMAC 504V in PDF format

Infusion: 

Overall Accuracy:      

+/- 5% of the selected Infusion Rate with assigned I.V. set

 

Setting Modes:           

Flow rate only, flow rate + volume target, time + volume target

 

Flow Rate Ranges:       

0.1 – 999 ml/hr

Infusion Volume limits

0.1 - 9999 ml

Time range

0-99:59 hrs

Bolus Rate

100 – 1000 ml/hr adjustable in the steps of 100 ml/hr

Bolus Volume

0.1 – 9999 ml

Purge Rate

 

KVO rate

1 to 5 % of selected infusions rate but minimum ml/hr

Mechanical:

Pumping Mechanism:     

Linear Peristaltic

Other: 

Drop Sensor

External (Optional for the detection of upstream occlusion)

 

Air Bubble Detector

Ultrasonic, Adjustable bubble size from 50-150ml

Accumulated bubble size of 1ml over period of 15 minutes

 

Set Type

JMS, BBRAUN, BAXTER, POLIMED, ROMSON

Facility to configure two customizable sets as per user’s choice

 

Occlusion

Programmable 3 Levels

 

LOW   0.5 +/0.10 Kg/cm2 (bar)

MID    0.9 +/0.20 Kg/cm2 (bar)

HIGH  1.2 +/0.25 Kg/cm2 (bar)

 

Indicators & Alarms: 

Audio Visual Alarms

 

No Mains, Very low battery, Low battery, Sensor error, Flow error, Door open, Near End, End of infusion, KVO, Air in line, Downstream Occlusion, Upstream Occlusion, Empty Container, System error, Pump stopped

 

Indicators

Run & Mains

 

Special Features: 

Free Flow Protection

 

A unique lever mechanism protects from free flow in case of accidental door opening

 

Upstream Occlusion Detection (Optional)

 

Optional Drop sensor for the detection of upstream occlusion besides the downstream occlusion

Adjustable air in line Alarm threshold

 

The size of air bubble to be detected can be set in the range of 50 to 150ml

 

Bolus and Purge facility

 

Adjustable bolus rate and bolus volume alongwith the Purge facility

 

Keypad locking

A built in safely feature prevents any change the parameter if any key is accidentally pressed during infusion

Power Supply: 

External power supply

AC Input range 170~ 270 V AC, Frequency 50 ~ 60 Hz, 12 Volts, 3 Amp DC output Supply

 

Power Consumption

30 Watt max.

 

Build in battery

8.4 V, 2.5 Ahr Ni-MH battery for increased durability

 

Battery life

Continuous operation for about 3.5 hrs. at an operating rate of 25 ml/hr with assign I.V. Set under standard conditions

 

Classification:

Operating conditions: 

Ambient Temperature

05 to 40° C

Relative Humidity 

20 to 90 % (no condensation)

Atmospheric Pressure 

70 to 106 kPa

Housing & Construction

Housing Material

Compact and Robust ABS Plastic

Weight

Approx. 2.4 Kgs

Dimensions

Approx. 250(L) mm, 145(H) mm, 90(W) mm

Mounting

On a pole or a bed-frame